  |
|   |
Product |
|
|
|
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa |
|
|
|
|
Version with E1 approval, Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Automatic drift compensation, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: AMP connector 6-pin , 2 m fixed cablefa |
|
|
|
|
Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Preset version, Version with switches determine sensing field, Automatic drift compensation, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: AMP connector 6-pin , 2 m fixed cablefa |
|
|
|
|
Version with E1 approval, Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: Fixed cable 3 m, halogen-free, with ferrite corefa |
|
|
|
|
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: 5 m fixed cablefa |
|
|
|
|
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC / 12 ... 28 V AC, Signal output: Relay, 1 alternator, Connection: 5 m fixed cablefa |
|
|
|
|
Version with E1 approval, Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: Fixed cable 3 m, halogen-free, with ferrite corefa |
|
|
|
|
Single-beam monitoring with extremely narrow sensor, Integrated circuit, Test, Simple installation - Plug & Play, Ideal for installation in door profiles or frames, Construction type(S2): Rectangular type, Test input, Light source: IRED, Light type: modulated infrared light, Operating voltage: 11 ... 30 V DC, Test input: Test: Transmitter switches off at +UB ≤ 5 V DC, Switching type: light-on, Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collectorfa |
|
|
|
|
Miniature design, Ideal for installation in door profiles or frames, Dark-On switching, Supplied with connection cable, Construction type(S2): Rectangular type, Test input, Light source: IRED, Light type: modulated infrared light , 880 nm, Operating voltage: 11 ... 30 V DC, Test input: emitter deactivation at +UB ≤ 5 V DC, Switching type: dark-on, Signal output: 1 NPN output, short-circuit protected, reverse polarity protected, open collectorfa |
|
|
|
|
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 300 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V DC, Signal output: 2 PNP, complementary, short-circuit protected, open collectors, Connection: Connector, Binder series 581, 5-pinfa |
|
  |
|   |