  |
|   |
Product |
|
|
|
Switching function: Normally open (NO), Output type: PNP, Output polarity: DC, Output type: 3-wire, Construction type: Slot, Series: Slot type, Type of voltage: DC, Connection type: 65 mm PVC cord with DuPont connector, Housing material: PBT, Degree of protection: IP67fa |
|
|
|
|
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Ga: PTB 99 ATEX 2219 Xfa |
|
|
|
|
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Ga: PTB 99 ATEX 2219 X, Equipment protection level Gb: PTB 99 ATEX 2219 Xfa |
|
|
|
|
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Gb: PTB 99 ATEX 2219 X, Equipment protection level Da: PTB 99 ATEX 2219 X, Connection type: flexible leads, Housing material: PBTfa |
|
|
|
|
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091Xfa |
|
|
|
|
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Type of voltage: DC, Connection type: flexible leads, Housing material: PBT, Degree of protection: IP67, Material: LIFYW, Length: 30 mm ± 4 mmfa |
|
|
|
|
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Gb: PTB 99 ATEX 2219 X, Equipment protection level Da: PTB 99 ATEX 2219 X, Connection type: flexible leads LiY, Housing material: PBTfa |
|
|
|
|
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Gb: PTB 99 ATEX 2219 X, Equipment protection level Da: PTB 99 ATEX 2219 Xfa |
|
|
|
|
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Ga: PTB 99 ATEX 2219 Xfa |
|
|
|
|
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X, Equipment protection level Gb: PTB 00 ATEX 2049 X, Equipment protection level Da: PTB 00 ATEX 2049 Xfa |
|
  |
|   |