Product |
|
|
|
Single head system, Analog output 0.5 ... 4.5 V, Measuring window adjustable, Program input, Series: -18GM, Operating voltage: 10 ... 30 V DC, Output type: 1 analog output 0.5 ... 4.5 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable, Housing: brass, nickel-platedfa |
|
|
|
|
Single head system, Short version: 55 mm, Function indicators visible from all directions, Switching output, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-058090, Connection type: Connector plug M12 x 1 , 4-pinfa |
|
|
|
|
Multi-head system, Large sensing range, Large possible lateral distance between emitter and receiver, Separate evaluation, Sensing range: 0 ... 15000 mm , emitter - receiver synchronised, Series: -F54, Operating voltage: 16 ... 30 V DC , ripple 10 %SS 8 V DC with reduced transmitting power, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 4-pin, Housing: PBTfa |
|
|
|
|
Multi-head system, Large sensing range, Large possible lateral distance between emitter and receiver, Separate evaluation, Sensing range: 0 ... 15000 mm , emitter - receiver synchronised, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 pulse output for echo run time, open collector NPN, short-circuit proof 0 level (active): UOL ≤ 2 V, IOL ≤ 15 mA 1 level (inactive): UOH = UB (pull-up R = 330 kOhm)fa |
|
|
|
|
Multi-head system, Large sensing range, Large possible lateral distance between emitter and receiver, One or two transducers connectable, Sensing range: 0 ... 15000 mm , emitter - receiver synchronised, Operating voltage: 16 ... 30 V DC , ripple 10 %SS 8 V DC with reduced transmitting power, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 Vfa |
|
|
|
|
Single head system, Thickness measurement with analog output 4 ... 20 mA, Extremely narrow projection cone, Short response time, Series: -12GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 4-pin, Housing: brass, nickel-platedfa |
|
|
|
|
Single head system, Thickness measurement with analog output 0 ... 10 V, Automatic compensation of the reference distance, deactivateable, Extremely narrow projection cone, Series: -12GM, Operating voltage: 15 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 4-pinfa |
|
|
|
|
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple) In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 current output 0 ... 20 mA rising ramp , UL approval: cULus Listed, General Purposefa |
|
|
|
|
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple) In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NC, Output type: 1 current output 0 ... 20 mA rising ramp , UL approval: cULus Listed, General Purposefa |
|
|
|
|
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple) In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 voltage output: 0 ... 10 V rising ramp , UL approval: cULus Listed, General Purposefa |
|
  |
|   |