Serviceline Industrial Sensors
Serviceline Explosion Protection

Diffuse and Retroreflective Mode Sensors

Choose your product

First PagePrevious PageNext PageLast Page
Product

 
Single head system, High chemical resistance, Analog current and voltage output, PTFE coated transducer, Series: UC-30GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit, Output type: 1 current output 4 ... 20 mA
1 voltage output 2 ... 10 V, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 Vfa

 
Single head system, Thread M50, Physical LIN interface, Temperature compensation, Series: -50GK, Operating voltage: 8 ... 18 V DC , ripple 10 %SS, Interface type: Physical LIN interface, Connection type: fixed cable with plug, Housing: Polyester (GRP)fa

 
Single head system, Thread M50, PTFE coated transducer, Physical LIN interface, Series: -50GK, Operating voltage: 8 ... 18 V DC , ripple 10 %SS, Interface type: Physical LIN interface, Connection type: fixed cable with plug, Housing: PBTfa

 
Single head system, Thread M50, PTFE coated transducer, Physical LIN interface, Series: -50GK, Operating voltage: 8 ... 18 V DC , ripple 10 %SS, Interface type: Physical LIN interface, Connection type: fixed cable with plug, Housing: PBTfa

 
Ultrasonic sensor, Analog current and voltage output, Synchronization options, Adjustable acoustic power and sensitivity, Series: -30GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit, Output type: 1 current output 4 ... 20 mA
1 voltage output 0 ... 10 V, UL approval: cULus Listed, General Purpose, Connection type: Connector plug M12 x 1 4-pinfa

 
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 current output 4 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purposefa

 
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NC, Output type: 1 current output 4 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purposefa

 
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 current output 0 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purposefa

 
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NC, Output type: 1 current output 0 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purposefa

 
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 voltage output: 0 ... 10 V rising ramp  , UL approval: cULus Listed, General Purposefa
First PagePrevious PageNext PageLast Page

Filter By