Serviceline Industrial Sensors
Serviceline Explosion Protection

FieldConnex Fieldbus Infrastructure

Choose your product

First PagePrevious PageNext PageLast Page
Product

 
FieldBarrier Junction Box, Brushed Stainless Steel, 8, 10, 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk
Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa

 
Ethernet-APL field junction box enclosure solution, glass-fiber reinforced polyester with intrinsically safe spur ports, Glass-fiber reinforced polyester (GRP) enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area
Zone 2, Device coupler location [2]: Zone 2pa

 
Ethernet-APL field junction box enclosure solution, brushed stainless steel with intrinsically safe spur ports, Stainless steel enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area
Zone 2, Device coupler location [2]: Zone 2pa

 
Ethernet-APL field junction box enclosure solution, brushed stainless steel with intrinsically safe spur ports, Stainless steel enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area
Zone 2, Device coupler location [2]: Zone 2pa

 
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Zone 1/2 - intrinsically safe high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa

 
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Zone 1/2 - intrinsically safe high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunk, Device coupler location [3]: Zone 1 - high-power trunkpa

 
Multi-Input/Output Junction Box, Brushed Stainless Steel, For discrete inputs and outputs, Brushed enclosure, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Zone 1/2 - intrinsically safe high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa

 
4 ... 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk, Instrument location / spur protection: non-explosion hazardous area
Zone 2 - all relevant types of protection
Zone 1 - increased safetypa

 
Segment Protector Junction Box, Brushed Stainless Steel, 4 ... 12 outputs Ex ic (FISCO or Entity), Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa

 
Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler, Design / Mounting: Outside installationpa
First PagePrevious PageNext PageLast Page

Filter By

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …

The Quick Select Product Guide for interface technology, FieldConnex®, and remote I/O connection technologies will help you select the right technology and systems when designing plants.