  |
|   |
Product |
|
|
|
FieldConnex® Fieldbus, Surge protector, threaded, for installation via threaded inlet in field housing (Ex d), IP67, Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunkpa |
|
|
|
|
FieldConnex® Fieldbus, Surge protector, threaded, for installation via threaded inlet in field housing (Ex ia), IP67, Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europepa |
|
|
|
|
FieldBarrier Junction Box, Brushed Stainless Steel, 4, 8 or 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
FieldBarrier Junction Box, Brushed Stainless Steel, 8, 10, 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
Ethernet-APL field junction box enclosure solution, glass-fiber reinforced polyester with intrinsically safe spur ports, Glass-fiber reinforced polyester (GRP) enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area Zone 2, Device coupler location [2]: Zone 2pa |
|
|
|
|
Ethernet-APL field junction box enclosure solution, brushed stainless steel with intrinsically safe spur ports, Stainless steel enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area Zone 2, Device coupler location [2]: Zone 2pa |
|
|
|
|
Ethernet-APL field junction box enclosure solution, brushed stainless steel with intrinsically safe spur ports, Stainless steel enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area Zone 2, Device coupler location [2]: Zone 2pa |
|
|
|
|
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Zone 1/2 - intrinsically safe high-power trunk Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa |
|
|
|
|
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Zone 1/2 - intrinsically safe high-power trunk Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunk, Device coupler location [3]: Zone 1 - high-power trunkpa |
|
  |
|   |