Product |
|
-
F2-JB-I*.*
-
Field Junction Box
-
FieldConnex® Fieldbus
-
|
|
FieldConnex® Fieldbus, Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: Zone 1 - intrinsically safe trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
FieldConnex® Fieldbus, Fieldbus barrier, stand-alone device in aluminum housing for field installation, 4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunkpa |
|
|
|
|
FieldConnex® Fieldbus, Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation, For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation, For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Temperature multi-input, stand-alone device with aluminum housing for field installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Temperature multi-input, stand-alone device with aluminum housing for field installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canadapa |
|
|
|
|
Ethernet-APL field junction box interface enclosure solution with remote I/O, brushed stainless steel with intrinsically safe spur ports, Stainless steel interface enclosure with remote I/O and Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area Zone 2, Device coupler location [2]: Zone 2pa |
|
|
-
MB-FB-GTR1*
-
Power Hub Motherboard
-
FieldConnex® Fieldbus
-
|
|
FieldConnex® Fieldbus, Power hub motherboard for protocol gateways modules, For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa |
|
|
-
MBHC-FB-4*
-
Power Hub Motherboard
-
FieldConnex® Fieldbus
-
|
|
FieldConnex® Fieldbus, Power hub motherboard with common host interface, 4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Power hub motherboard for gateway and power supply modules, 4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics, IECEx approval, International, Europe, USA, Canadapa |
|
  |
|   |