  |
|   |
Product |
|
|
|
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Protective lid, padlockable, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Protective lid, padlockable, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Emergency stop shroud with padlock, Bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Emergency stop shroud with padlock, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Emergency stop shroud with padlock, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Key-release emergency mushroom button, red - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Key-release emergency mushroom button, red - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Key-release emergency mushroom button, red - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Pushbutton green - 1x NO / 1x NC - labeling 'l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: push button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
|
|
|
Pushbutton green - 1x NO / 1x NC - labeling 'l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Bottom face cable gland polyamide, 1x M25, Function: push button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa |
|
  |
|   |