Product |
|
|
|
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092Xfa |
|
|
-
SJ5-N
-
Inductive slot sensor
-
|
|
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Ga: PTB 99 ATEX 2219 Xfa |
|
|
|
|
Evaluation unit exclusively for the ultrasonic sensor system USi-safety, Categorie 3 PL d (EN ISO 13849) for each ultrasonic transducer without redundancy, Multiple device installation possible, no mutual interference (no cross-talk), Safety outputs OSSD, Sensing range: 1 ... 250 cm typ. 200 cm, Performance level (PL): PL d, Operating voltage: 21 ... 28 V DC typ. 24 V DC, Interface type: USB 2.0, Output type: safety output OSSD Normally closed, Power FET PNP OSSD 1.1 and OSSD 1.2fa |
|
|
|
|
G12 safety module, 2 safety inputs and 2 standard electronic outputsfa |
|
|
|
|
Moving presence sensor for automatic doors, SIL 2, certified in accordance with DIN 18650/EN 16005, Exceptional detection reliability, Reliable operation with all floor coverings, Complete protection up to the wall without sensor shutoff, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 24 V DC +/- 20 %, Signal output: switchable NPN or PNP , short-circuit protected, Connection: Plug-in terminal with 6-wire connection cablefa |
|
|
|
|
Read head for incident light positioning system, SIL 3 (EN 61508), PROFINET interface, Category 4 PL e (EN ISO 13849), PROFIsafe interface, Safe, non-contact positioning on Data Matrix code tape, Traverse distance up to 100 km , Mechanically rugged: no wearing parts, long operating life, maintenance-free, Output of code quality, Pollution detectionfa |
|
|
|
|
Read head for incident light positioning system, SIL 3 (EN 61508), Category 4 PL e (EN ISO 13849), PROFINET interface, PROFIsafe interface, Safe, non-contact positioning on Data Matrix code tape, Traverse distance up to 100 km , Mechanically rugged: no wearing parts, long operating life, maintenance-free, Output of code quality, Pollution detectionfa |
|
|
|
|
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouplepa |
|
|
|
|
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouplepa |
|
|
|
|
2-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DCpa |
|
  |
|   |