Serviceline Industrial Sensors
Serviceline Explosion Protection

Products for Safety Applications

Choose your product

First PagePrevious PageNext PageLast Page
Product

 
1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1 and 3 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1 and 2 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1, 2, 3 and 4 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 2 and 3 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1, 2, 3 and 6 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1, 3, 4 and 6 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1, 2, 4 and 5 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 2, 3, 5 and 6 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1, 2, 3, 4, 5 and 6 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa

 
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Output type: 2-wire, Construction type: Slot, Series: Slot type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0091X, Equipment protection level Gb: IECEx PTB 11.0091X, Equipment protection level Da: IECEx PTB 11.0091X, Equipment protection level Mb: IECEx PTB 11.0091X, Equipment protection level Ga: PTB 99 ATEX 2219 Xfa
First PagePrevious PageNext PageLast Page

Filter By

Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.