Serviceline Industrial Sensors
Serviceline Explosion Protection

Products for Safety Applications

Choose your product

First PagePrevious PageNext PageLast Page
Product

 
2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA, current sink, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 18 mm, Number of channels: 2-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: 2-wire transmitterpa

 
4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 passive transistor outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508, Housing width: 18 mm, Number of channels: 4-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 4 x Transistor (passive), Fault indication outputpa

 
2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Up to SIL 3 acc. to IEC/EN 61508 (loop powered), Housing width: 18 mm, Number of channels: 2-channel, Filter, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 20.4 ... 30 V DC loop powered
20.4 ... 30 V DC bus powered via Termination Boardpa

 
1-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Reduced intrinsically safe parameters, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: 2-wire transmitterpa

 
4-channel isolated barrier, 24 V DC supply (bus powered), Analog in or analog out signals, Sink and source mode outputs, SMART pass-through, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 18 mm, Number of channels: 4-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20.4 ... 30 V DC bus powered via Termination Boardpa

 
1-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
1-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 6 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
1-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 6 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa
First PagePrevious PageNext PageLast Page

Filter By

Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.