Product |
|
|
|
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa |
|
|
|
|
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 6 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa |
|
|
|
|
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 6 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa |
|
|
|
|
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 5 ... 25 V 1), Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092Xfa |
|
|
|
|
OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stop function Cat.0 or Cat.1 and central stop function Cat.0, Time function, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing, Connection: Cage tension spring terminals , Cable cross-section 0.2 ... 1.5 mm2fa |
|
|
|
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing, Connection: Cage tension spring terminals , Cable cross-section 0.2 ... 1.5 mm2fa |
|
|
|
|
Muting module, 4 sensor channels, Double muting, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housing, Connection: Cage tension spring terminals , Cable cross-section 0.2 ... 1.5 mm2fa |
|
|
|
|
Muting module, 4 sensor channels, Double muting, Continuous muting with no time limit, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housing, Connection: Cage tension spring terminals , Cable cross-section 0.2 ... 1.5 mm2fa |
|
|
|
|
Sensor module, 4 sensor channels, Micro-Controller controls, Operating mode can be selected by means of DIP switches, Individual module for SLA5(S), SLA20, SLA25, SLA28 and SLA40 security through-beam sensors; for SLP safety light grids, for SLC safety light curtains; for switching pads and emergency stop buttons of categories 2 or 4, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4fa |
|
  |
|   |