Producto |
|
|
|
Segment Protector Junction Box, Brushed Stainless Steel, Connection of Ex d certified devices, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Zone 1/2 - intrinsically safe high-power trunk Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa |
|
|
|
|
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Zone 1/2 - intrinsically safe high-power trunk Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa |
|
|
|
|
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Zone 1/2 - intrinsically safe high-power trunk Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa |
|
|
|
|
Temperature Multi-Input Junction Box, Brushed Stainless Steel, 8 channel universal temperature interface, Brushed enclosure, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Zone 1/2 - intrinsically safe high-power trunk Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa |
|
|
-
F2-JB-*.*
-
Field Junction Box
-
FieldConnex® Fieldbus
-
|
|
FieldConnex® Fieldbus, Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity, Europe, Device coupler location: non-explosion hazardous area, Instrument location / spur protection: non-explosion hazardous area, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
-
F2-JB-I*.*
-
Field Junction Box
-
FieldConnex® Fieldbus
-
|
|
FieldConnex® Fieldbus, Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: Zone 1 - intrinsically safe trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
FieldConnex® Fieldbus, Fieldbus barrier, stand-alone device in aluminum housing for field installation, 4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunkpa |
|
|
|
|
FieldConnex® Fieldbus, Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation, For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation, For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canadapa |
|
  |
|   |