Producto

 
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Protective lid, padlockable, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Protective lid, padlockable, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Emergency stop shroud with padlock, Bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Emergency stop shroud with padlock, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Emergency stop shroud with padlock, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Key-release emergency mushroom button, red - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Key-release emergency mushroom button, red - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Bottom face cable gland polyamide, 1x M25, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Key-release emergency mushroom button, red - 1x NO / 1x NC, Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Top face stopping plug polyamide, 1x M20; bottom face cable gland polyamide, 1x M20, Function: mushroom button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Pushbutton green - 1x NO / 1x NC - labeling 'l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Bottom face cable gland polyamide, 1x M20, Function: push button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa

 
Pushbutton green - 1x NO / 1x NC - labeling 'l', Polyamide (PA) enclosure, Ex db eb and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Pushbutton with interchangeable inserts, Degree of protection IP66, Bottom face cable gland polyamide, 1x M25, Function: push button, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F) @ T4
-40 ... 40 °C (-40 ... 104 °F) @ T6, Enclosure: Polyamide (PA)pa
Primera páginaPrevious PagePágina siguienteÚltima página

Seleccionar producto por

Guía de selección rápida para equipos de protección contra explosiones eléctricas

Consiga una copia en PDF gratis de nuestra guía de selección rápida para equipos de protección contra explosiones eléctricas. Ofrece una descripción completa de toda nuestra gama de productos.

Si el pedido es dentro de Europa, su caja de terminales Ex e o unidad de control local personalizadas estarán listas para enviarse en sólo cinco días. Utilice nuestras herramientas en línea para configurar rápidamente su propia solución…

Destacado: Seis preguntas para Schober Herbert

Pepperl+Fuchs ofrece a sus clientes unidades de control personalizadas, cajas de terminales e interruptores de desconexión para zonas peligrosas, incluida la certificación, en tan sólo cinco días. Schober Herbert nos cuenta más sobre esta parte de la gama de equipos de protección contra explosiones eléctricas.