Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones

Unidades de control (Ex e)

Elige tu producto

Primera páginaPrevious PagePágina siguienteÚltima página
Producto

 
LED indicator, red, Double pushbutton, red/green - 1x NO / 1x NC - labeling '0 - l', Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Stainless Steel AISI 316L, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Ex db eb and Ex tb certified, Pushbutton with interchangeable inserts, Bottom face cable gland polyamide, 1x M25, Wide range of accessories available, Function: LED, Function 2: double pushbutton, Function 3: mushroom buttonpa

 
Pushbutton green - 1x NO / 1x NC - labeling 'l', Pushbutton red - 1x NO / 1x NC - labeling '0', Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Stainless Steel AISI 316L, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Ex db eb and Ex tb certified, Pushbutton with interchangeable inserts, Bottom face cable gland polyamide, 1x M25, Wide range of accessories available, Function: push button, Function 2: push button, Function 3: mushroom buttonpa

 
LED indicator, red, Pushbutton green - 1x NO / 1x NC - labeling 'l', Pushbutton red - 1x NO / 1x NC - labeling '0', Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Stainless Steel AISI 316L, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Ex db eb and Ex tb certified, Pushbutton with interchangeable inserts, Bottom face cable gland polyamide, 1x M25, Function: LED, Function 2: push button, Function 3: push button, Function 4: mushroom buttonpa

 
Emergency stop mushroom button 40 mm, red, twist-to-release - 1x NO / 1x NC, Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: mushroom button 40 mm, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Contact block 1x NC, Component for approprately certified Ex e enclosures, Mounting on enclosure cover, Ex ia certified, Polyamide, Function: Illuminated pushbutton module, Housing: Polyamide (PA), Marking: [exsign] II 1 G
Ex ia IIC Ga

pa

 
Contact block 1x NC, Component for approprately certified Ex e enclosures, Mounting on enclosure cover, Ex de certified, Polyamide, Function: Illuminated pushbutton module, Housing: Polyamide (PA), Marking: [exsign] II 2 G
Ex db eb IIC Gbpa

 
Contact block 1x NO, Component for approprately certified Ex e enclosures, Mounting on enclosure cover, Ex ia certified, Polyamide, For use with enclosure types SR*, Function: Illuminated pushbutton module, Housing: Polyamide (PA), Marking: [exsign] II 1 G
Ex ia IIC Ga

pa

 
Contact block 1x NO, Component for approprately certified Ex e enclosures, Mounting on enclosure cover, Ex de certified, Polyamide, For use with enclosure types SR*, Function: Illuminated pushbutton module, Housing: Polyamide (PA), Marking: [exsign] II 2 G
Ex db eb IIC Gbpa

 
Glass fiber reinforced polyester (GRP) enclosure, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex de, Ex ib and Ex tb certified, Up to 4 operators per enclosure, Customizable configuration of operators, cable entry quantities and cable gland types as per specification, Wide range of labels and accessories available, 2 enclosure size options, Degree of protection IP66, Function: see data table, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F)
-50 °C (-58 °F) on requestpa

 
Polyamide (PA) enclosure, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex db eb, Ex ib and Ex tb certified, Up to 5 operators per enclosure, Customizable configuration of operators, contact modules and cable entries as per specification, Wide range of labels and accessories available, 5 enclosure size options, Degree of protection IP66, Installation in portrait, landscape on request, Function: see data table, Ambient temperature: -40 ... 55 °C (-40 ... 131 °F)
-50 °C (-58 °F) on requestpa
Primera páginaPrevious PagePágina siguienteÚltima página

Seleccionar producto por

Guía de selección rápida para equipos de protección contra explosiones eléctricas

Consiga una copia en PDF gratis de nuestra guía de selección rápida para equipos de protección contra explosiones eléctricas. Ofrece una descripción completa de toda nuestra gama de productos.

Si el pedido es dentro de Europa, su caja de terminales Ex e o unidad de control local personalizadas estarán listas para enviarse en sólo cinco días. Utilice nuestras herramientas en línea para configurar rápidamente su propia solución…

Destacado: Seis preguntas para Schober Herbert

Pepperl+Fuchs ofrece a sus clientes unidades de control personalizadas, cajas de terminales e interruptores de desconexión para zonas peligrosas, incluida la certificación, en tan sólo cinco días. Schober Herbert nos cuenta más sobre esta parte de la gama de equipos de protección contra explosiones eléctricas.