Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones

Unidades de control (Ex e)

Elige tu producto

Primera páginaPrevious PagePágina siguienteÚltima página
Producto

 
Pushbutton, inserts red, green, amber, white, blue, black - 2x NO - no labeling, Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: push button, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Potentiometer, black - 0.5 kOhm - labeling '0 - 10', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: potentiometer, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Potentiometer, black - 10 kOhm - labeling '0 - 10', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: potentiometer, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Potentiometer, black - 1 kOhm - labeling '0 - 10', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: potentiometer, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Potentiometer, black - 2 kOhm - labeling '0 - 10', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: potentiometer, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Key switch, 2 position with left OFF - 1x NO / 1x NC - labeling '0 - l', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: key switch, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Key switch, 2 position with left OFF - 2x NO - labeling '0 - l', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: key switch, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Small control switch, 2 position - 1x NO / 1x NC - labeling 'l - ll', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: control switch, small, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Small control switch, 3 position with center OFF - 2x NO - labeling 'l - 0 - ll', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: control switch, small, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa

 
Small control switch 3 position with left OFF - 1x NO / 1x NC - labeling '0 - l - ll', Ex de and Ex tb certified, Full equipment certified, Polyamide housing for panel mount, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable Gland M20 integrated in protective cover, Degree of protection IP66, Function: control switch, small, Housing: Polyamide (PA), Marking: [exsign] II 2 GD
Ex de IIC T6 Gb
Ex tb IIIC T80 °C Dbpa
Primera páginaPrevious PagePágina siguienteÚltima página

Seleccionar producto por

Guía de selección rápida para equipos de protección contra explosiones eléctricas

Consiga una copia en PDF gratis de nuestra guía de selección rápida para equipos de protección contra explosiones eléctricas. Ofrece una descripción completa de toda nuestra gama de productos.

Si el pedido es dentro de Europa, su caja de terminales Ex e o unidad de control local personalizadas estarán listas para enviarse en sólo cinco días. Utilice nuestras herramientas en línea para configurar rápidamente su propia solución…

Destacado: Seis preguntas para Schober Herbert

Pepperl+Fuchs ofrece a sus clientes unidades de control personalizadas, cajas de terminales e interruptores de desconexión para zonas peligrosas, incluida la certificación, en tan sólo cinco días. Schober Herbert nos cuenta más sobre esta parte de la gama de equipos de protección contra explosiones eléctricas.