Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones

Prensaestopas

Elige tu producto

Primera páginaPrevious PagePágina siguienteÚltima página
Producto

 
For cables without armor, Thread M40, Thread length 10 mm, Ex eb and Ex tb certified, Blue marking for use with Ex i circuits, High impact-resistant polyamide material, Seal chloroprene, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Very large clamping range due to double sealing insert, Full impact resistance of 7 J according to IEC/EN 60079-0 for the full range without limitations, Cable type: non-armored cables, Thread size (TD): M40, Cable gland: high impact-resistant polyamidepa

 
For cables without armor, Thread M40, Thread length 15 mm, Ex eb and Ex tb certified, Blue marking for use with Ex i circuits, High impact-resistant polyamide material, Seal chloroprene, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Very large clamping range due to double sealing insert, Full impact resistance of 7 J according to IEC/EN 60079-0 for the full range without limitations, Cable type: non-armored cables, Thread size (TD): M40, Cable gland: high impact-resistant polyamidepa

 
For cables without armor, Thread M50, Thread length 18 mm, Ex eb and Ex tb certified, Blue marking for use with Ex i circuits, High impact-resistant polyamide material, Seal chloroprene, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Very large clamping range due to double sealing insert, Full impact resistance of 7 J according to IEC/EN 60079-0 for the full range without limitations, Cable type: non-armored cables, Thread size (TD): M50, Cable gland: high impact-resistant polyamidepa

 
For cables without armor, Thread M63, Thread length 18 mm, Ex eb and Ex tb certified, Blue marking for use with Ex i circuits, High impact-resistant polyamide material, Seal chloroprene, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Very large clamping range due to double sealing insert, Full impact resistance of 7 J according to IEC/EN 60079-0 for the full range without limitations, Cable type: non-armored cables, Thread size (TD): M63, Cable gland: high impact-resistant polyamidepa

 
For cables without armor, Thread M16, Thread length 10 mm, Ex eb and Ex tb certified, Blue marking for use with Ex i circuits, High impact-resistant polyamide material, Seal chloroprene, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Very large clamping range due to double sealing insert, Full impact resistance of 7 J according to IEC/EN 60079-0 for the full range without limitations, Cable type: non-armored cables, Thread size (TD): M16, Cable gland: high impact-resistant polyamidepa

 
For armored cables, Brass nickel-plated or stainless steel, Metric and NPT versions available, Ex d, Ex e and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4Xpa

 
For armored cables, Barrier gland, Brass nickel-plated or stainless steel, Metric and NPT versions available, Seal silicone, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable type: armored cables, Clamping range (D): see data table, Thread size (TD): see data table, Cable gland: brass nickel-plated or AISI 316 (1.4401) stainless steel, O-Ring: silicone, Seal insert: silicone, Marking: [exsign] II 2 GD
Ex db IIC Gb
Ex eb IIC Gb
Ex tb IIIC Dbpa

 
For cables without armor, Barrier gland, Brass nickel-plated or stainless steel, Metric and NPT versions available, Seal silicone, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Cable type: non-armored cables, Clamping range (D): see data table, Thread size (TD): see data table, Cable gland: brass nickel-plated or AISI 316 (1.4401) stainless steel, O-Ring: silicone, Seal insert: siliconepa

 
For cables without armor, Brass nickel-plated or stainless steel, Metric and NPT versions available, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Connection of flexible metallic conduitspa

 
For shielded EMC cables without armor, Brass nickel-plated or stainless steel, Metric and NPT versions available, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4Xpa