Serviceline Industrial Sensors
Serviceline Explosion Protection

Modules for DIN Rail Mounting

Choose your product

First PagePrevious PageNext PageLast Page
Product

 
Surge protection for 2 signal lines, Nominal voltage 180 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 12.5 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per linepa

 
Protection module for 2 signal lines, Nominal voltage 180 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 12.5 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per linepa

 
Surge protection for 2 signal lines, Nominal voltage 230 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 6 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 3 kA per linepa

 
Protection module for 2 signal lines, Nominal voltage 230 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 6 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 3 kA per linepa

 
Two-part monitoring device, Device set with transmitter/receiver and reverse unit, Fault indication via LED, Status indication output, Modularity: two-piece, Display elements: status display
operating state (green)
fault indication (red), Device suitable for mounting in equipment protection level: Gcpa

 
For surge protection system M-LB-4000, Isolation acc. to IEC 60079-11, Color blue, DIN rail mountablepa

 
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

 
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa
First PagePrevious PageNext PageLast Page

Filter By

Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.

Intelligent Surge Protection M-LB-5000

The M-LB-5000 surge protection system offers a combination of diagnostics and modularity within a narrow housing design of only 6.2 mm width. Explore the easiest way to protect plant assets …